- Can I use an air sampler in an ATEX-classified area? — Yes, if the instrument is certified for that zone. Directive 1999/92/EC requires the employer to classify areas into zones (0, 1, 2 for gases and vapours; 20, 21, 22 for dusts); Directive 2014/34/EU divides equipment into categories: category 1 goes in zones 0 and 20, category 2 in zones 1 and 21, category 3 in zones 2 and 22.
- How is the microbiological quality of compressed air checked? — Air, nitrogen and other gases in contact with the product or critical surfaces must be filtered at the point of use with integrity-tested 0.22 µm sterilising filters and monitored for particles, microbial count, water and oil. EU GMP Annex 1 treats them as part of the Contamination Control Strategy.
- Does moving from paper forms to software improve monitoring data integrity? — It can, if the system is validated and well configured: a non-editable audit trail, defined users and roles, a synchronised clock, verified backups. Software alone is not enough: ALCOA+ principles apply to every record, paper or electronic.
- How do I find the content for my sector? — From the Sectors section: each sector has its own page with what is measured, risks and controls, suitable instruments and links to the notes, guides, glossary entries and standards that concern it.
- How do you go from the plate count to CFU per cubic metre? — Divide the number of colonies by the volume of air sampled and scale it to 1000 litres. Example: 20 CFU counted after a 200-litre sample equal 20 × 1000 / 200 = 100 CFU/m³. To express the result per cubic foot, multiply the value per litre by 28.32.
- Two identical samplers give different results: why? — Because microorganisms are not evenly distributed in the air, and the low counts typical of cleanrooms vary a lot from one sample to the next. Before suspecting the instrument, check that both samples were taken at the same point, under the same conditions and with the same volume, and that both instruments were decontaminated and calibrated.
- What is the difference between an in-house check and calibration of the sampler? — An in-house check is carried out by company staff to confirm that the instrument works and is not damaged, for example after a fall or with a worn battery. Calibration is performed with traceable instruments, often by an external laboratory, and produces the certificate that inspectors ask to see.
- How long can the tube connecting the probe to the particle counter be? — The reference is ISO/TR 14644-21:2023: under 1 metre. Direct sampling without tubing remains the first choice; tubing is used only to reach a critical location otherwise inaccessible, and must be kept short and straight. Two metres may be justified for a fixed counter in a RABS, provided bends are limited and a risk assessment is documented.
- What is an audit trail and why do inspectors always ask for it? — It is the automatic, system-generated record of who created, modified or deleted a datum, when and why, without erasing the previous value. Inspectors ask for it because it is the only proof that an electronic result was not altered after the fact.
- What is the difference between 21 CFR Part 11 and Annex 11? — They cover the same ground (GMP computerised systems and electronic data) from two sides of the Atlantic. Part 11 (FDA, 1997) is a rule on electronic records and signatures; Annex 11 (EU, 2011; revision in draft since 2025) is guidance on the computerised system lifecycle. A site exporting to both markets must meet both.
- What is the QMSR and what changes for medical device makers? — It is the rewritten 21 CFR Part 820: from 2 February 2026 FDA requires medical device manufacturers to run a quality system compliant with ISO 13485:2016, incorporated by reference, instead of the old 1996 Quality System Regulation. Those already ISO 13485 certified for the European market have the right structure.
- Why is the Grade A microbial limit "no growth" rather than "<1 CFU"? — Because the 2022 text (§9.30, Table 6) wants to remove any ambiguity: in Grade A any microbial recovery must be investigated, with no averaging or rounding. The wording also opens the door to rapid methods, which do not express results in CFU. Same logic behind the ban on averaging against the limits of other grades.
- Why did the ≥5 µm limit in Grade A move from 20 to 29 particles/m³? — To align with ISO 14644-1:2015, which for ISO Class 5 calculates 29 particles/m³ at 5 µm. The 2007 value of 20 was a GMP threshold inconsistent with the technical standard. Annex 1 (§4.28) warns, however, that in Grade A repeated ≥5 µm counts even below the limit may signal a problem (filters, equipment, practices) and must be investigated.
- How many aseptic process simulations (APS) are needed and when? — At least three consecutive for a new line, after changes to HVAC, equipment, process, shifts or personnel, after a major shutdown, after relocation and after a failure. Routinely twice a year for each process, line and shift; every operator at least once a year; one before decommissioning or relocating the line. Acceptance criterion: zero contaminated units.
- Does vapour-phase hydrogen peroxide (H₂O₂) sterilise isolators? — No: Annex 1 classes it as surface bio-decontamination, not sterilisation, because it does not penetrate and its reproducibility depends on load, humidity and geometry. Direct and indirect product contact parts (needles, pumps, stopper bowls, guides) must therefore be sterilised separately (autoclave, tunnel, steam-in-place) and assembled in Grade A.
- What is the difference between HACCP and HARPC? — HACCP is the Codex Alimentarius system, mandatory in the EU (Reg. 852/2004): seven principles centred on critical control points. HARPC is the version required by FDA under FSMA (21 CFR 117, 2015): same framework, but hazards are assessed "without assuming controls already in place", preventive controls go beyond CCPs (sanitation, allergens, suppliers, recall) and the plan is entrusted to a PCQI.
- Is environmental monitoring in a food plant a critical control point? — Normally not. A CCP is a process step with a measurable critical limit and an immediate action on the product (pasteurisation, metal detection). Environmental monitoring is a prerequisite programme (GHP) under Codex and a "sanitation preventive control" under HARPC: it verifies that the environment is under control, with alert and action levels derived from history, not critical limits.
- What are VACCP and TACCP and who requires them? — They are two extensions of HACCP to intentional hazards. VACCP assesses vulnerability to economically motivated food fraud (substitution, dilution, counterfeiting); TACCP assesses malicious threats (sabotage, extortion), based on BSI PAS 96. They are required by GFSI schemes (BRCGS, FSSC 22000, IFS, SQF) and, in the US, by the FSMA Intentional Adulteration rule (21 CFR 121) for food defence.
- What is CCIT and why is it so talked about in 2026? — Container Closure Integrity Testing verifies that vial, stopper and seal maintain sterility and barrier throughout shelf-life. USP <1207> requires defining for each product the maximum allowable leakage limit (MALL) and using deterministic methods (vacuum or pressure decay, helium, HVLD, laser) able to detect it, instead of probabilistic ones (microbial or dye ingress).
- Why were there so many visible-particulate recalls in 2026? — Between July and September 2026 the FDA recorded at least eleven recalls of injectables and infusion solutions for visible particles: glass, stainless steel, glass fibres, cotton and wood, nylon, iron oxide. USP <790> requires 100% inspection of units and statistical sampling for release: it catches the defect but does not explain it.
- I have a TNTC plate in Grade A: what should I do? — Record it as TNTC without estimating a number, still identify the isolates and open an investigation as a serious excursion. In Grade A or ISO 5 the expectation is zero: an uncountable plate almost always indicates a macroscopic event (barrier breach, undecontaminated material, infestation) and is not closed without tracing the cause.
- What changes with the new EU GMP Chapter 1 of 2026? — Chapter 1 "Pharmaceutical Quality System" has been rewritten to align with ICH Q9(R1) and Q10: structured knowledge management, lifecycle risk management, a streamlined Product Quality Review with product grouping and shortage prevention among PQS objectives. Applicability expected in 2027, after a transition period.
- Can I use the classification table limits as monitoring limits? — Not as the only limits. The classification table gives maxima by grade; Annex 1 §9.9 requires monitoring alert levels and action limits to be set on qualification results, the nature of the process, data trends and the Contamination Control Strategy. The action limit may coincide with the regulatory maximum, but the alert level must sit below it, within the real operating range of the process.
- If monitoring always gives zero, is the environment under control? — Only if the system producing that zero would have been able to see contamination. A zero is credible when the sampler has demonstrated collection efficiency (EN 17141), the sampling location is where the risk to the product is highest (§9.7), sampling covers the full duration of critical processing (§9.24) and media have passed growth promotion. If one of these conditions is missing, the zero…
- Can I transform counts (log, square root) to read trends better? — Yes, for reading and analysis: when raw counts have peaks and high variance, square root or logarithm make the trend readable and stabilise variance for control charts. The constraint is data integrity: the raw value remains recorded, unaltered, traceable and retained for the required period; the transformation is a view, not a replacement datum.
- What is AROUND LAB NEWS? — AROUND LAB NEWS is an educational, knowledge-sharing channel devoted to quality, safety and hygiene in the analytical laboratory, with a focus on contamination control, environmental monitoring and cleanrooms. It collects, verifies and organises technical content (glossary, standards, guides, application notes, a directory of bodies and societies) to make an otherwise fragmented field…
- Who curates the content and how? — Content is curated through multi-source verification: every glossary entry, standard or organisation profile is traced back to official documents (standards bodies, regulatory authorities, scientific societies) before publication. The goal is educational clarity, not promotion: we explain the “why” of a requirement, not just the “what”.
- Is AROUND LAB NEWS independent from suppliers? — Yes, editorially. Technical information is chosen for its educational value, and every fact is checked against official sources. When a topic concerns an activity covered by an ORUM INTERNATIONAL, TRIO.BAS or STATIM LAB instrument, the page shows it with photos and data taken from the official pages, naming the instrument relevant to the topic and its limits of use. Promotional spaces are…
- Is the site available in more than one language? — Yes. Every page can be read in Italian, English, Spanish and Portuguese: the language selector at the top right changes the language of all main content, glossary, standards, guides, notes, directory and events included.
- What is contamination control? — Contamination control is the set of strategies, procedures and technologies aimed at preventing, reducing and controlling contamination (microbial, particulate and chemical) of products, surfaces and critical environments. In pharma it is a cross-cutting requirement covering facility design, flows of people and materials, sanitisation, gowning and monitoring.
- What is a Contamination Control Strategy (CCS)? — The CCS is the documented strategy (explicitly required by EU GMP Annex 1 in its 2022 revision) through which a site demonstrates that it has identified, assessed and kept under control all sources of contamination in an integrated way. It is not a single formal document, but the map of technical and organisational controls and their overall effectiveness.
- What is a cleanroom? — A cleanroom is an environment in which the concentration of airborne particles is controlled within defined limits and where temperature, humidity, differential pressure and airflow are also governed. Particle classification follows ISO 14644-1; in EU GMP, environments are additionally graded A, B, C and D according to the activities performed.
- What is the difference between particulate and microbial contamination? — Particulate contamination concerns inert airborne particles, measured with optical particle counters and classified by size (e.g. ≥0.5 µm and ≥5 µm). Microbial contamination concerns viable microorganisms, detected via active air sampling, settle plates and contact plates. They are distinct but related quantities: particles can act as carriers for microorganisms.
- What do grades A, B, C, D mean in GMP? — They are the cleanliness classes of pharmaceutical environments defined by Annex 1. Grade A is the highest-risk zone (aseptic filling, critical interventions) under unidirectional airflow; grade B is its background in aseptic processing; grades C and D are controlled environments for less critical stages. Each grade has particulate and microbiological limits, “at rest” and “in operation”.
- What is environmental monitoring (EM)? — Environmental monitoring is the systematic programme for detecting microbial and particulate contamination in production environments. It covers air (active and passive), surface and personnel sampling, with frequencies, sampling points and alert/action levels defined on the basis of risk assessment and the environment’s grade.
- What is the difference between active and passive air sampling? — Active sampling draws a known volume of air and impacts it onto a culture medium, giving a quantitative result (CFU per cubic metre). Passive sampling uses settle plates exposed for a defined time and measures microbial deposition over an area (CFU per plate/time). The two methods are complementary in the EM programme.
- What are contact plates for? — Contact plates have a convex agar surface that is pressed onto flat surfaces or the operator’s gloves to detect contact microbial contamination. They are the standard tool for monitoring surfaces and personnel in classified areas.
- What are alert and action levels? — They are predefined thresholds that interpret monitoring data. The alert level flags a departure from the expected trend and calls for attention; the action level indicates an exceedance requiring investigation and corrective action. They are set on a statistical and historical basis and are an integral part of the EM programme.
- What is EU GMP Annex 1 and why does it matter? — Annex 1 of the EU GMP governs the manufacture of sterile medicinal products. The revision published in 2022, in force since 25 August 2023 (with an extension to 25 August 2024 for certain lyophilisation provisions), strongly introduces the risk-based approach and the Contamination Control Strategy as the backbone of the entire contamination-control system.
- What does ISO 14644 establish? — The ISO 14644 series is the international standard for cleanrooms and associated controlled environments. Part 1 defines air cleanliness classification by particle concentration (ISO classes 1–9); other parts cover monitoring, testing, design and operation. It is the particulate reference also called up by GMP.
- What does ISO 14698 cover? — ISO 14698 addresses biocontamination control in cleanrooms: it provides principles and methodology to set up a microbiological monitoring system, define sampling points and evaluate data. It is the “biological” complement to ISO 14644, which instead focuses on particulate.
- What is ISO/IEC 17025 and who uses it? — ISO/IEC 17025:2017 specifies the general requirements for the competence of testing and calibration laboratories. A laboratory accredited to this standard demonstrates impartiality, technical competence and the ability to produce valid results. It is the internationally recognised reference standard for laboratory accreditation.
- What is the difference between accreditation and certification? — Certification attests the conformity of a management system or product to a standard (e.g. ISO 9001) and is issued by certification bodies. Accreditation is the formal recognition of the technical competence of a body (for example a laboratory to ISO/IEC 17025) and is issued by national accreditation bodies.
- What are rapid microbiological methods (RMM)? — RMM are techniques that are alternatives to traditional culture, reducing detection times or giving real-time results, based on principles such as cytometry, ATP bioluminescence or fluorescence. Their adoption requires validation against the reference method; in Europe the framework is set out by the Pharmacopoeia (Ph. Eur. 5.1.6).
- How are bacterial endotoxins determined? — Endotoxins are determined with the LAL (Limulus Amebocyte Lysate) assay in its variants (gel-clot, turbidimetric, chromogenic) and, increasingly, with recombinant Factor C (rFC), an alternative free of animal-derived reagents. The methods are described in the European Pharmacopoeia (2.6.14 and 2.6.32).
- What is a media fill (aseptic process simulation)? — A media fill is a simulation of the aseptic filling process in which a culture medium is used instead of the product to verify the process’s ability to maintain sterility. It is a periodic test required by GMP to validate aseptic operations and operator competence.
- Why is it important to identify recovered isolates? — Identifying the microorganisms recovered in monitoring helps reconstruct the source of contamination (people, materials, environment), assess its relevance to the product and guide corrective actions. It also provides the basis for controlling the site’s characteristic microbial flora.
- What is data integrity (ALCOA+)? — Data integrity is the assurance that data, whether paper or electronic, are complete, consistent and reliable throughout their life cycle. The principle is summarised by the acronym ALCOA+: data must be Attributable, Legible, Contemporaneous, Original, Accurate and, in the “plus”, complete, consistent, enduring and available.
- What is the Directory and how do I use it? — The Directory is the curated list of regulatory bodies, scientific societies, pharmaceutical associations, contamination-control societies and journals/portals of the sector, at national and international level. Each entry has a profile with description, scope and official link; you can filter by category or search by name.
- Where do I find the sector’s conferences and courses? — The Events section gathers conferences, courses and webinars on cleanrooms, monitoring and contamination control, indicating the organising body and linking to its Directory profile. Each event shows date, place and a description of the programme.
- How do I use the glossary? — The Glossary collects acronyms, classes and definitions of contamination control and cleanrooms. You can search a term, filter by category or browse the alphabetical index; each entry opens a card with the extended definition and related cross-references.
- What are “application notes”? — Application notes are operational deep-dives that translate a regulatory requirement or a method into practical guidance for the laboratory and the cleanroom. They cover topics such as sampling, method validation and data management, with verified and up-to-date references.
- Who are the “figures of microbiology”? — It is a section dedicated to the figures who shaped the history of microbiology, with biographical profiles and anniversaries. It gives historical depth to the concepts covered on the site, connecting current practice to the discoveries that made it possible.
- How can I contact you or propose content? — You can write to us through the form on the Contacts page: we use it for reports, collaboration proposals and requests for deeper coverage. We do not publish direct addresses to limit spam, but we read every message received through the form.
- What is unidirectional (laminar) airflow? — Unidirectional airflow is air moving at a uniform velocity along parallel streamlines, typically around 0.45 m/s, sweeping particles away from the critical zone. It is the defining feature of grade A zones (hoods and aseptic filling positions), where it protects the exposed product from any airborne contamination.
- What is the difference between an isolator and a RABS? — Both are barriers separating the operator from the critical aseptic processing zone. An isolator is a closed, sealed environment, automatically decontaminated (usually with vaporised hydrogen peroxide) and kept at positive pressure. A RABS (Restricted Access Barrier System) uses physical barriers and unidirectional airflow but is not fully sealed, so it requires a more stringent grade B…
- Why is gowning so important? — Humans are the main source of contamination in a cleanroom: they continuously shed particles and microorganisms. Gowning with dedicated garments, operator qualification and correct behaviour in the classified area are core controls of the contamination strategy, so much so that glove and gown monitoring is an explicit requirement in aseptic areas.
- What is the recovery test (recovery time)? — The recovery test measures the time a cleanroom takes to return to its cleanliness level after a controlled contamination, an indicator of the effectiveness of ventilation and air changes. ISO 14644-3 describes the methodology; in GMP, restoring “as built/at rest” conditions is a qualification parameter for the environment.
- How long are settle plates exposed? — In grade A/B aseptic processing, 90 mm settle plates are normally exposed for the whole duration of the critical activity, with a maximum time per single plate typically not exceeding 4 hours, so as not to impair the medium’s viability. The plates are then incubated and the results compared with the Annex 1 limits.
- What is personnel monitoring (finger dab)? — The finger dab, or glove print, is the microbiological sampling of the operator’s gloved fingertips onto a contact plate, performed at the end of critical activities. Together with gown monitoring, it is the direct check of the effectiveness of gowning and of behaviour in the classified area.
- Which culture media are used in environmental monitoring? — The most common medium for total count is TSA (Tryptic Soy Agar), suitable for bacteria and, in part, yeasts and moulds; for the fungal component Sabouraud Dextrose Agar (SDA) is often used. The choice of media, temperatures and incubation times must be justified and validated according to the flora expected at the site.
- What is trend analysis of monitoring data for? — Trend analysis looks at how monitoring data evolve over time, beyond the point-by-point comparison with limits, to catch gradual drifts before they become exceedances. It is a key element of the Contamination Control Strategy: it demonstrates that the state of control is maintained and guides preventive actions.
- What does ISO 14644-2 add to classification? — While part 1 defines air cleanliness classification, ISO 14644-2 sets the requirements for monitoring over time that demonstrates the classification is maintained. It shifts the focus from a single periodic test to a risk-based monitoring plan.
- What do DQ, IQ, OQ and PQ mean? — They are the phases of equipment and facility qualification: Design Qualification (suitability of the design), Installation Qualification (correct installation), Operational Qualification (operation within the intended parameters) and Performance Qualification (performance under real process conditions). They form the documented basis that precedes process validation.
- What is the European Pharmacopoeia (Ph. Eur.)? — The European Pharmacopoeia is the official, legally binding collection, in the adhering states, of monographs and analytical methods for medicines and substances. It contains the general chapters of reference for pharmaceutical microbiology, including sterility, microbial contamination of non-sterile products, endotoxins and rapid methods (5.1.6).
- What is bioburden? — Bioburden is the viable microbial load present on a product, raw material or surface before sterilisation. Controlling and periodically determining it is essential to size sterilisation processes and to demonstrate that the incoming microbial load stays within defined limits.
- What is the growth promotion test? — The growth promotion test verifies that a culture medium is able to grow reference microorganisms within expected times and characteristics. It is a mandatory quality control on every batch of medium used in microbiological control, because an ineffective medium would produce false negatives.
- What does the sterility test involve? — The sterility test verifies the absence of viable microorganisms in a product declared sterile, usually via membrane filtration or direct inoculation, followed by incubation. It is a final sample-based test described in the Pharmacopoeia, which complements, but does not replace, the sterility assurance guaranteed by the process and its validation.
- What are “objectionable” microorganisms? — They are microorganisms whose presence in a non-sterile product is unacceptable given the route of administration, the patient population and the product’s characteristics, for example specific pathogens or species able to spoil it. Their absence is assessed with the Pharmacopoeia’s specified-microorganisms tests.
- How often is the content updated? — Content is reviewed on an ongoing basis: standards, notes and directory are aligned with the current versions of the reference documents, while the Updates section gathers regulatory and enforcement news as it emerges. Each page shows, where relevant, the date of its last revision.
- Can I cite or reuse the site’s content? — The content is educational in purpose: it may be cited by indicating the source. For the use of text, images or profiles beyond simple citation, please contact us through the form so we can verify any third-party rights. For images we always indicate origin and conditions of use.
- What is H₂O₂ bio-decontamination? — Bio-decontamination with vaporised hydrogen peroxide (H₂O₂) is a sanitisation process for enclosed environments (typically isolators, RABS and rooms) in which peroxide in the vapour phase reaches surfaces and hard-to-access points uniformly, reducing the microbial load by several orders of magnitude. Its effectiveness is demonstrated with resistant-spore biological indicators.
- What is a pressure cascade between rooms? — A pressure cascade is the pressure difference maintained between adjacent rooms of different grades, so that air always flows from the cleaner to the less clean zone. Annex 1 gives a guidance value of about 10 Pa between rooms of different classes; pressures are continuously monitored and alarmed.
- What does “first air” mean? — “First air” is the air leaving the HEPA filter that has not yet met any surface: it is therefore the cleanest and must reach the critical point directly (product, open container, stopper). Interrupting first air with hands, tools or materials placed above the critical zone is one of the main risk causes in aseptic processing.
- Why are several disinfectants used, including a sporicide? — Annex 1 requires the use of more than one type of disinfectant and the periodic inclusion of a sporicidal agent, because ordinary disinfectants do not kill bacterial and fungal spores. Rotation also reduces the risk of selecting resistant microbial populations; product effectiveness must be validated on the facility’s actual surfaces.
- Is particle monitoring in grade A continuous? — Yes. For grade A, Annex 1 requires continuous particle monitoring for the ≥0.5 µm and ≥5 µm sizes throughout the duration of critical processing, with adequate sample volumes. A similar approach is recommended for grade B. Continuous monitoring detects transient events that periodic checks would miss.
- What are the microbiological limits for grade A? — For grade A, Annex 1 sets “no growth” as the action limit for the active air sample, settle plate, contact plate and glove print. Any recovery in grade A is treated as an event to be investigated. Grades B, C and D have increasing limits according to criticality.
- What is done in case of a monitoring excursion? — An excursion is an exceedance of an alert or action level. It requires recording the event, an investigation proportionate to criticality (with identification of microorganisms in grade A/B), assessment of the impact on the batches produced and the definition of corrective and preventive actions (CAPA). Excursion patterns feed into trend analysis.
- What is ICH Q9 (Quality Risk Management)? — ICH Q9 is the international guideline on quality risk management: it provides principles and tools (such as FMEA and risk analysis) to identify, assess and control risks across the product life cycle. It is the methodological reference for the risk-based approach called up by Annex 1; the revised version Q9(R1) dates from 2023.
- What is USP <797>? — USP <797> is the general chapter of the US Pharmacopeia devoted to sterile compounding, with requirements on environments, aseptic technique, beyond-use dating (BUD) and monitoring. The updated revision became official on 1 November 2023 and is the typical reference for US pharmacies and compounding units.
- What does ISO 14644-3 contain? — ISO 14644-3 describes the test methods for cleanrooms: from particle counting to filter-integrity tests, from air-velocity and airflow measurement to the recovery test and airflow visualisation. It is the technical reference for periodically qualifying and requalifying the environment’s performance.
- What is PIC/S and how does it relate to GMP? — PIC/S (Pharmaceutical Inspection Co-operation Scheme) is the co-operation scheme between the inspectorates of more than fifty countries, harmonising GMP and inspector training. Its GMP Guide and its Annex 1 are aligned with the European ones, supporting mutual recognition of inspections internationally.
- What are the D-value and F0 in sterilisation? — The D-value is the time needed, at a given temperature, to reduce a microbial population by 90% (one log); the z-value indicates by how many degrees the temperature must change to alter D tenfold. F0 is the equivalent sterilisation time at 121 °C (with z = 10 °C): the Pharmacopoeia reference moist-heat cycle is 15 minutes at 121 °C.
- What is a biological indicator? — A biological indicator is a standardised population of microbial spores particularly resistant to the process being verified, used to demonstrate its effectiveness. Geobacillus stearothermophilus is typically used for moist heat and vaporised hydrogen peroxide; Bacillus atrophaeus for dry heat and ethylene oxide. Their inactivation confirms that the required lethality has been achieved.
- What is MALDI-TOF identification? — MALDI-TOF is a mass-spectrometry technique that identifies a microorganism by comparing the “spectrum” of its proteins with a reference library, delivering identification within minutes from a single colony. It is now widely used in microbiological control for its speed and species-level reliability.
- What limits apply to Water for Injection (WFI)? — Water for Injection (WFI) is the highest-quality water for pharmaceutical use. The Pharmacopoeia sets an action limit for total microbial count of 10 CFU per 100 mL and a bacterial-endotoxin limit below 0.25 IU/mL. WFI can be produced by distillation or by suitably validated membrane techniques.
- Where can I follow you on social media? — We are on LinkedIn and Facebook, where we share regulatory updates, new content and news from the sector. Links to the profiles are available in the header and footer of every page of the site.
- Is the site accessible? — Yes: we work to make the site usable by as many people as possible, taking care of contrast, content structure and keyboard navigation. The Accessibility statement page describes the commitment we have made and how to report any difficulties in using the site.
- How do you handle personal data? — We process only the data that is necessary, for example that voluntarily submitted through the contact form, in compliance with the applicable law. The Privacy Policy and Cookie Policy pages explain what data we collect, for what purposes and how to exercise your rights; non-technical cookies are enabled only with your consent.
- What is a HEPA filter? — A HEPA (High Efficiency Particulate Air) filter is the high-efficiency air filter that retains at least 99.97% of particles at the most penetrating size (MPPS, around 0.3 µm). It is the element that generates the clean air supplied to cleanrooms; for more demanding applications ULPA filters, which are even more efficient, are used. The integrity of installed filters is verified periodically with…
- What are smoke studies (airflow visualisation)? — Smoke studies are airflow-visualisation tests in which a neutral smoke makes air movement visible in the critical zones. EU GMP Annex 1 explicitly requires them to demonstrate, under static and dynamic conditions, that unidirectional airflow protects the product and that there is no turbulence or stagnation at critical points. They are normally recorded as video.
- How are environmental monitoring plates incubated? — The plates exposed in environmental monitoring are incubated at temperatures and for times that are defined and validated according to the flora to be recovered: a common scheme uses a lower range, favourable to yeasts and moulds, followed by a higher one for bacteria. The choice must be justified and supported by studies demonstrating recovery of the expected microorganisms.
- What is EudraLex Volume 4? — EudraLex Volume 4 is the official collection of EU GMP guidelines for medicinal products for human and veterinary use. It comprises a Part I (finished products), a Part II (active substances) and a series of thematic Annexes, including Annex 1 on sterile products and Annex 11 on computerised systems. It is the baseline regulatory reference for the European pharmaceutical industry.
- What are viable but non-culturable (VBNC) microorganisms? — VBNC (Viable But Non-Culturable) microorganisms are cells that are still viable and potentially hazardous but that, under certain stress conditions, do not grow on traditional culture media and therefore escape the classic count. The phenomenon is one of the reasons for the interest in rapid microbiological methods, which can detect viability without requiring growth.
- Do you have a newsletter? — Yes. We publish a newsletter on LinkedIn with regulatory updates, new content and news from the sector. You can subscribe from the dedicated button in the site footer, which links to the official AROUND LAB NEWS newsletter on LinkedIn.
- What is sampling in microbiology? — Sampling is the set of operations by which a portion (the sample) is taken from a batch, a surface or an environment to estimate its microbiological characteristics. Since not everything can be tested, the validity of the result depends on how representative the sample is and on correct collection, transport and storage procedures.
- What does a “representative sample” mean? — A sample is representative when it faithfully reflects the actual distribution of microorganisms in the batch or environment it comes from. It is obtained by taking several increments at different points and combining them according to a defined plan: a non-representative sample can lead to wrong decisions, both false compliant and false non-compliant.
- What are two-class and three-class sampling plans? — They are statistical schemes, formalised by the ICMSF, that define how many units to test (n) and how many may exceed a limit before the batch is rejected (c). In a two-class plan each unit is acceptable or not against a limit m; a three-class plan adds an upper limit M separating a tolerated zone (between m and M) from an unacceptable one.
- How are surfaces sampled? — Surfaces are sampled mainly with contact plates on flat, regular surfaces, or with swabs and sponges for irregular, large or hard-to-reach surfaces. The reference standard for food is ISO 18593; in GMP, surface monitoring is an integral part of the environmental programme, with limits per cleanroom grade.
- How is water sampled for microbiological analysis? — Sampling is performed aseptically, in sterile containers, letting the water run and, for treated networks, neutralising any residual disinfectant (e.g. with sodium thiosulfate). ISO 19458 defines the purposes and modalities of sampling; ISO 5667 provides general guidance. The sample must be analysed within a short time and kept refrigerated.
- Why is mycotoxin sampling so critical? — Because mycotoxins are distributed in “hot spots”: a few highly contaminated particles in an otherwise clean mass. A single increment can therefore massively over- or under-estimate the real level. This is why Reg. (EU) 2023/2782 requires collecting many increments at different points, forming a representative aggregate sample and reducing it by fine grinding and homogenisation before analysis.
- How are biological samples transported? — Potentially infectious biological samples normally fall under category B and travel as UN 3373 “Biological substance, category B”, with the triple packaging required by packing instruction P650 of the ADR: a leak-proof primary container, absorbent secondary packaging and a rigid outer packaging. Where needed, the cold chain is maintained.
- What determines how many samples to take? — The size and homogeneity of the batch, the risk associated with the product and the required confidence level. Tools such as the AQL (Acceptable Quality Level) and the operating characteristic (OC) curve describe the probability of accepting or rejecting a batch as a function of n and c: increasing the number of units reduces the risk of wrong decisions, at a higher analytical cost.
- What does Annex 11 require for computerised systems? — Annex 11 of the EU GMP sets the expectations for computerised systems used in regulated activities: risk management, validation, access control, an audit trail recording who did what and when, change control and continuity in case of failure. On the IT side it is the twin of the data-integrity requirements.
- Is ISO 14644 a single standard or a family? — It is a family of parts covering different aspects of cleanrooms. Part 1 classifies air cleanliness by particles (ISO classes 1–9); part 2 covers monitoring; part 3 test methods; part 4 design and start-up. Specialist parts follow: 8 on airborne chemical contamination, 9 on particles on surfaces, 10 on chemical surface contamination, 12 on airborne nanoparticles, 13 and 14 on equipment…
- What is the Monocyte Activation Test (MAT)? — The MAT is an in-vitro method that detects pyrogens by measuring the response of human immune cells. Unlike the LAL test, which detects only bacterial endotoxins, the MAT picks up a broader range of fever-inducing substances and is described by the European Pharmacopoeia (2.6.30) as an alternative to the rabbit test.
- What is the log reduction value (LRV)? — The LRV measures how much a process lowers the microbial load, on a logarithmic scale: 1 log is a 90% reduction, 3 log is 99.9%, 6 log is 99.9999%. It is the standard way to express the effectiveness of sterilisation, filtration and disinfection.
- What is PUPSIT? — PUPSIT stands for Pre-Use Post-Sterilisation Integrity Test: the integrity test of a sterilising filter carried out after sterilisation but before use. It rules out that flaws masked during sterilisation compromise the filtration. The EU GMP Annex 1 expects it as standard practice, unless justified on a risk basis.
- What is airborne molecular contamination (AMC)? — AMC are contaminants in gas or vapour form (acids, bases, volatile organic compounds) that particle filters do not retain and that can damage sensitive products and processes. They are classified by ISO 14644-8 and matter above all in microelectronics and some pharmaceutical operations.
- What is mean kinetic temperature (MKT)? — MKT is a single temperature that summarises the effect of temperature excursions on a product or sample during transport and storage, weighting higher temperatures more according to degradation kinetics. It is used to judge whether short excursions remain acceptable; the reference is the ICH Q1A(R2) stability guideline.
- Why a section devoted to historical figures? — Because today’s techniques (culture, sterilisation, filters, cleanrooms) grew out of precise discoveries by specific people. Reconstructing who first measured, isolated or classified something helps explain the “why” of a method, not just the procedure. The profiles gather verified figures from microbiology, hygiene and contamination control.
- What role does metrology play in the lab? — Metrology is the science of measurement: calibration, uncertainty, traceability and instrument drift. It is the neutral ground under every figure: a count or a classification is only as good as the instrument that produced it. That is why the site gives it a dedicated strand, independent of any instrument brand.
- How is the number of sampling locations worked out under ISO 14644-1:2015? — No longer from the square root of the area: it is read from Table A.1 by area. Locations generally increase, for example from 6 to 9 in a 36 m² room.
- Why does the site say “vaporised hydrogen peroxide” and not “VHP”? — Because VHP is a registered trademark. As with RODAC, which we replace with “contact plates”, we use the generic name of the technology.
- Does a positive PCR result prove that live microorganisms are present? — No. PCR also detects DNA from dead cells: on its own it does not prove that viable microorganisms are present.
- Can artificial intelligence be used in GMP decisions? — Not yet as a GMP rule: Annex 22, which will regulate it, is a 2025 draft not yet adopted. In the draft, critical applications allow only static, deterministic models, validated with independent test data and with human oversight proportionate to risk.
- In what environment can a blow-fill-seal machine be installed? — Under Annex 1 (2022) a BFS machine with an effective Grade A air shower may sit in at least a Grade C environment, with Grade A/B garments.
- How does an authority join PIC/S, and which countries joined recently? — An applicant authority is assessed on legislation, GMP standards, inspection resources and quality system, through a dossier review and an on-site visit. Once a member, it is reassessed periodically.
- What are WHO maturity levels for regulatory authorities? — WHO assesses national regulatory systems with the Global Benchmarking Tool and rates them on four maturity levels: level 1 means some basic elements exist, level 2 an evolving system, level 3 a stable and integrated system, level 4 the most advanced.
- Is a test report from an accredited laboratory valid abroad? — Generally yes, if the body that accredited the laboratory is a signatory of the ILAC mutual recognition arrangement (ILAC MRA). Signatory bodies recognise reports from laboratories accredited by other signatories as equivalent.
- Are GMPs the same on every continent? — In substance yes, because many authorities adopt the PIC/S or the WHO GMP guide; the legal text and the dates differ, though. In the European Union the reference is EudraLex Volume 4, in the United States 21 CFR 210/211. Brazil, with ANVISA RDC 658/2022 (30 March 2022), adopted the PIC/S guidelines as minimum requirements; India revised Schedule M (G.S.R. 922(E), 28 December 2023) to align it…
- Are the endotoxin and sterility tests the same in Europe, the United States and Japan? — They are separate texts, but harmonised. Bacterial endotoxins are covered by Ph. Eur. 2.6.14, USP <85> and JP 4.01; the sterility test by Ph. Eur. 2.6.1, USP <71> and JP 4.06. The Pharmacopoeial Discussion Group (PDG) harmonised these chapters and the ICH Q4B guidelines recognise them as interchangeable in the ICH regions.
- Is an HACCP plan also required outside Europe? — The seven HACCP principles come from the Codex Alimentarius (CXC 1-1969, 2020 revision) and are taken up by many laws, with different names and details. In the European Union Regulation (EC) 852/2004 requires HACCP-based procedures; in the United States FSMA (21 CFR 117) uses the HARPC model, with hazard analysis and preventive controls. In Brazil ANVISA RDC 275/2002 requires standard operating…
- How are materials and equipment brought into Grades A and B? — Annex 1 sets an order of preference. First, sterilisation with direct pass-through, for example a double-door autoclave opening on the clean side. If that is not possible, sterile materials in multiple wrapping, with the outer layer disinfected at each change of grade, or rapid transfer ports (RTPs) connected to the isolator. Any other method must be justified and validated.
- Is Annex 3 on radiopharmaceuticals changing? — Yes. The Annex 3 in force dates from 2008. In December 2025 EMA and PIC/S published a concept paper to revise it, open for public consultation from 15 December 2025 to 15 February 2026. The revision aims to cover areas the current text does not address, clarify some sections and support innovative manufacturing and control approaches.
- Does Annex 1 apply to advanced therapies (ATMPs)? — ATMPs have their own GMP guide, Part IV of EudraLex Volume 4, adopted in 2017. Since the 2023 Annex 1, Part IV is no longer aligned: for example, it does not include the contamination control strategy (CCS) or barrier systems. EMA therefore put a revision concept paper out for consultation from May to July 2025, to align it with Annex 1 while keeping a flexible approach.
- Where do reference strains for testing come from? — From recognised culture collections, which keep strains under a catalogue number and guarantee their identity and purity. In Europe, for example, DSMZ (Germany), NCTC and NCIMB (UK), the Institut Pasteur’s CIP (France), CECT (Spain) and CBS (Netherlands); in the United States ATCC, in Japan NBRC and JCM.
- Is a 100 or a 200 litres per minute air sampler better? — It depends on the volume you need and how long you can stay at the point. At 100 l/min it takes 10 minutes to sample 1,000 litres; at 200 l/min it takes 5. In cleanrooms, where contamination is low and large volumes are sampled, 200 l/min saves operator time.
- How long can a settle plate be left open? — Up to 4 hours. In Grades A and B plates cover the whole operation, including equipment assembly, and are changed within 4 hours. In Grades C and D time and frequency are based on risk, still within 4 hours.
- How do I set up a risk-based environmental monitoring plan? — Start from a documented risk assessment that identifies sampling points, frequencies and limits based on activities, airflows and how critical each zone is. The plan covers air (active and passive sampling), surfaces and personnel, and links to the Contamination Control Strategy (CCS) required by the 2022 Annex 1.
- How do I build a surface monitoring plan? — Choose the points based on risk, for example product-contact surfaces and areas that are handled often, then define frequencies and limits. Use contact plates for flat surfaces and swabs for irregular ones, usually at the end of the operation so the process is not disturbed.
- What is the contamination recovery rate in USP <1116>? — It is the percentage of samples, or plates, that show microbial recovery in a given class of environment. USP <1116> proposes it because zero contamination at every point and in every aseptic operation is not technically possible: what counts is how often recovery occurs over time, more than any single result.
- When and how are operators' gloves and gowns sampled in Grades A and B? — Personnel are monitored in Grades A and B, in addition to air and surfaces. The typical sample is a fingerprint of all five fingers of each hand on a culture plate, while for the gown 55 mm contact plates are used on points such as the forearms and chest. Points and frequencies are set through a risk assessment.
- What is the EU reference value for Legionella in buildings, and which method measures it? — Directive (EU) 2020/2184 sets a parameter value for Legionella below 1,000 colony-forming units (CFU) per litre (Annex I, part D), within the risk assessment of domestic distribution systems. The reference method is culture according to EN ISO 11731.
- How do I handle an out-of-specification (OOS) result in a cleanroom? — An Out of Specification (OOS) is a limit exceedance on a classification or monitoring result, either particle or microbiological. The investigation starts with a laboratory phase (instruments, method, sampling, analytical errors) and, if the result is confirmed, moves to an extended phase covering product and area.
- How is gowning qualified for operators working in the aseptic area? — Gloves and suit are sampled after gowning and at the exit from critical sessions, repeating the test a defined number of times to demonstrate the operator's competence. The results feed the list of personnel authorised for each grade; materials are qualified according to ISO 14644-18.
- Is the HEPA filter integrity test the same as the factory efficiency test? — No. The in-situ integrity test checks that the installed filter has no leaks in the media, sealant or frame. A challenge aerosol (typically PAO/DEHS) is generated upstream and the surface and sealing perimeter are scanned downstream with a photometer. Factory efficiency, by contrast, concerns the media alone.
- How long should alcohol hand rubbing last, and when is washing with soap and water needed? — According to the 2009 guidelines of the WHO (World Health Organization), for hands that are not visibly soiled the preferred method is rubbing with an alcohol-based product, which takes 20-30 seconds in total. Washing with soap and water takes 40-60 seconds and is mandatory when hands are visibly soiled.
- Why is a neutralizer needed in microbial counts, and how is method suitability shown? — Residues of disinfectants, preservatives or active ingredients inhibit growth and give falsely low counts. The neutralizer (for example lecithin or polysorbate 80) inactivates them. Suitability is shown by inoculating a low number of colony-forming units (CFU) of reference strains and comparing recovery with a positive control.
- How are mycoplasmas detected in biological products and cell cultures? — Compendial testing (Ph. Eur. 2.6.7, USP <63>) combines the culture method on specific media with the indicator cell culture method, in which a DNA dye reveals mycoplasmas attached to the cells. Both take a long time, up to several weeks.
- How do I show that a disinfectant works in a cleanroom? — Efficacy must be shown in the laboratory with standardised European tests, because a «bactericidal» label alone is not enough. In the suspension test (for example EN 1276) the disinfectant stays in contact with a known suspension of microorganisms for a defined time and the log reduction is calculated; a typical criterion is ≥ 5 log.
- Is it better to use dehydrated or ready-to-use culture media? — It depends on where you want the responsibility to sit. Dehydrated media are cheap and flexible, but preparation in the laboratory, from weighing to sterilisation, remains with the user and an error affects every test. Ready-to-use media reduce variability and the risk of error, with batches already checked, at a higher cost and with shelf-life constraints.
- How do I run a deviation investigation and find the root cause? — Describe the problem, contain it straight away (for example by isolating the batch or stopping the process), then look for the cause that, once removed, prevents recurrence. The 5 whys and the Ishikawa diagram help separate the root cause from mere symptoms.
- How do I correct an error on a GMP record? — Draw a single line through the error so that it stays legible, then add signature, date and reason. Nothing is erased or overwritten. The principle is that in GMP «if it is not recorded, it did not happen»: records are the proof of compliance.
- How is the z-score of a proficiency test interpreted? — A proficiency test (PT) is a comparison in which a provider distributes identical samples to several laboratories, which are then evaluated against a reference value. With |z| ≤ 2 the result is satisfactory, between 2 and 3 it is questionable, and from 3 upwards it is unsatisfactory.
- How is the Risk Priority Number (RPN) calculated in FMEA? — FMEA (Failure Mode and Effects Analysis) gives each failure mode three scores: severity (S), probability of occurrence (O) and detectability (D). Their product, RPN = S × O × D, ranks risks by priority and shows where to act.
- How uncertain is a colony count on a plate, and why aim for the 25-250 range? — If microorganisms are randomly distributed in a well-mixed liquid, colony counts follow the Poisson distribution and the relative uncertainty is about 1/√N: with 100 colonies it is 10%, with 25 it rises to 20%. This is why plate counts aim for 25-250 CFU (colony-forming units).
- When is the MPN method preferable to a plate count? — The Most Probable Number (MPN) estimates the concentration of viable microorganisms from positive and negative tubes at serial dilutions, without counting colonies. It suits difficult samples, such as turbid water, water with particulates or disinfectant residues, or samples with few cells; if the plate works, it remains the first choice.
- How are E. coli and coliforms detected in water with ISO 9308-1? — A known volume of water is filtered through a 0.45 µm membrane that retains the bacteria, then the membrane is placed on a selective chromogenic medium and incubated. Coliform and E. coli colonies show distinct colours thanks to the enzymes β-galactosidase and β-glucuronidase and are counted directly.
- What is ISO 13485 and who does it apply to? — It is the international quality management system standard for organisations that design, manufacture, install or service medical devices. It builds on ISO 9001 and departs from it on one point: it asks for the effectiveness of the system to be maintained, without setting continual improvement as a goal.
- What is FSSC 22000 and how does it go beyond ISO 22000? — It is a food safety certification scheme recognised by the GFSI (Global Food Safety Initiative). It rests on ISO 22000:2018 and adds the sector prerequisite programmes of the ISO/TS 22002 series plus requirements of its own.
- What is the difference between USP <61> and USP <62>? — Chapter <61> counts the microorganisms in non-sterile products: total aerobic microbial count (TAMC) and total yeast and mould count (TYMC). Chapter <62> instead looks for the presence or absence of specified microorganisms, chosen by route of administration, after enrichment.
- How does the antimicrobial effectiveness test in USP <51> work? — The product is inoculated with five strains (C. albicans, A. brasiliensis, E. coli, P. aeruginosa, S. aureus) and survivors are counted at set intervals up to 28 days. It shows that the preservative system withstands the microorganisms that enter the container during use.
- What is the contamination recovery rate in USP <1116>? — It is the percentage of samples showing any microbial growth, regardless of the number of colonies. The chapter proposes it for trending aseptic environments, where most counts are zero. It is an informational chapter, so it is not mandatory.
- Who does ICH Q7 apply to and how does it link to the European GMP Guide? — ICH Q7 is the good manufacturing practice guide for active pharmaceutical ingredients (APIs). It covers the route from the point where the starting material enters the process to the packaging of the API. In the EU it is Part II of the GMP Guide.
- What is 21 CFR Part 211 and why does it appear in Warning Letters? — It is the part of the Code of Federal Regulations containing the binding cGMP (current Good Manufacturing Practice) for finished medicinal products intended for the US market. For cleanrooms and contamination control it is the US counterpart of the European GMP and Annex 1.
- Is the 2004 FDA guidance on aseptic processing mandatory? — No. It is a non-binding guidance: those who follow it are generally considered compliant, but different approaches are allowed if they meet the CGMP (current Good Manufacturing Practice). Inspectors use it as the basis of inspection programme 7356.002A.
- How does ISO 18593 say to sample surfaces? — The standard picks the technique according to the surface. Contact plates suit flat, smooth, non-porous surfaces; sponges or cloths are used for large, rough or irregular ones. Swabs are for small areas or hard-to-reach spots.
- What is the difference between food safety criteria and process hygiene criteria? — Food safety criteria say whether a product or lot placed on the market is acceptable: if exceeded, it must be withdrawn or recalled. Process hygiene criteria say whether production is working acceptably and lead to corrective actions.
- Which method is used to count Legionella in drinking water? — For culture-based counting the EN ISO 11731 is used. Directive (EU) 2020/2184 names it for checking the Legionella parameter value in domestic distribution systems: less than 1,000 CFU/L. The directive allows alternative methods of at least equal reliability.
- Is the revised Schedule M already mandatory for all Indian manufacturers? — Yes. From 1 January 2026 the revised Schedule M applies to all medicine manufacturers in India. It was notified on 28 December 2023 as G.S.R. 922(E) and rewritten to align it with the WHO (World Health Organization) GMP.
- Which GMP apply in Brazil and where are the requirements for sterile products? — The base rule is Anvisa's RDC 658 of 30 March 2022, which adopts the general PIC/S GMP guidelines as minimum requirements for all companies that make medicines. The requirements for sterile products are in IN (normative instruction) No. 35 of 21 August 2019.
- What do «Class 100» or «Class 10,000» mean in old cleanroom documents? — They are the classes of the US standard FED-STD-209E, withdrawn on 29 November 2001 and replaced by the ISO 14644 series. They were based on particles of 0.5 µm or larger per cubic foot. The standard no longer has binding force.
- Why must a particle counter be calibrated to ISO 21501-4? — The standard defines the calibration method for light-scattering optical particle counters and sets their performance parameters, such as counting efficiency, size resolution and flow rate. Without an instrument calibrated this way, the data would be neither comparable nor defensible.
- How is the dose set in radiation sterilization? — The absorbed dose, expressed in kGy, is set by relating the product's bioburden to the required SAL (sterility assurance level). It is not chosen arbitrarily. The process works with gamma, electron beam and X-rays.
- What microbiological limits apply to non-sterile products under Ph. Eur. 5.1.4? — They depend on the route of administration and cover the total aerobic microbial count (TAMC) and the total yeast and mould count (TYMC), in CFU per g or mL. They are 10³ and 10² for non-aqueous oral forms and rectal ones, 10² and 10¹ for aqueous oral forms and the other routes.
- How is a pipette calibrated under ISO 8655? — With the reference gravimetric method of Part 6: ten water deliveries at each test volume are weighed on an analytical balance, correcting for density, temperature and evaporation. Mean and spread are then compared with the limits of the relevant part.
- How is subvisible particulate matter in injectables measured under USP <788>? — With two methods: light obscuration, which is the first choice, and microscopy, used when the product is not suited to the first or as confirmation. Limits are expressed at the 10 µm and 25 µm thresholds.
- What changes with the new EN 12469 on biological safety cabinets? — The standard was published in November 2025 in several parts, which replace EN 12469:2000. For class II cabinets it no longer sets one air velocity for all: the values declared by the manufacturer apply, to be demonstrated also under degraded conditions.
- How often should a cleanroom be requalified? — Under Annex 1, Grade A and B rooms are requalified every 6 months and Grade C and D rooms every 12. Requalification follows the initial qualification, which checks the design phase by phase, each in its own occupancy state.
- What must the HVAC system of a cleanroom ensure? — HVAC, the air handling system, supplies air filtered through HEPA or ULPA and the air changes needed to dilute the particles generated during operation. It also keeps temperature, humidity and pressure differentials within design limits.
- How do you check that a HEPA filter is truly leak-tight? — With an in situ leak test: a PAO or DOP aerosol is generated and the surface and gaskets are scanned for leaks above the allowed threshold. The stated efficiency, at least 99.95% for class H13, holds only if the filter is intact and well fitted.
- How many air changes per hour does a cleanroom need? — There is no single value for all rooms. Air changes per hour (ACH) tell you how many times an hour the room volume is replaced with filtered air. The right number depends on class, load and layout, and must be confirmed by measured performance.
- What does a particle counter measure and what affects the quality of its data? — The optical particle counter (OPC) draws a known volume of air and detects scattered light to count and size particles, with typical thresholds at 0.5 and 5 µm depending on the grade. Data quality depends on calibration, sampling lines and probe position.
- How is operating room air classified in Italy? — The reference is UNI 11425:2011, which sorts rooms into three levels according to ISO 14644: very high (ISO 5), high (ISO 7) and standard (ISO 8). Verification takes place under simulated operating conditions.
- How do you qualify a laboratory incubator or refrigerator? — It starts with thermal mapping, empty and loaded, to find hot and cold spots. Monitoring sensors are then placed at the worst-case points, with high and low alarms, and temperature is recorded continuously.
- Can an out-of-specification microbiological result simply be repeated? — No. An OOS (out of specification) or OOT (out of trend) result calls for a structured investigation. The laboratory phase first looks for obvious errors, but the result is not invalidated without a demonstrated cause.
- How is an operator authorised to enter Grades A and B alone? — An initial gowning assessment is needed, repeated at least once a year (Annex 1 §7.4), with a visual check and contact plates on gloves, forearms, chest and hood. Unsupervised access comes after a passed gowning assessment and a successful media fill.
- How do you monitor the air inside an isolator or RABS without opening the barrier? — Only the sterile sampling head stays inside the barrier, made of materials resistant to decontamination with H₂O₂ (hydrogen peroxide); controls and data stay outside. This way no door is opened and no arm is put in to change a plate.
- What do you check before opening an OOS investigation on the endotoxin test? — First you confirm the assay was valid: USP <85> requires recovery of the added endotoxin between 50% and 200%. An invalid assay is not handled as an OOS, though it is still worth finding out why it failed.
- When does a media fill fail and what do you do? — Under the 2022 Annex 1, a single contaminated unit is enough. The investigation looks for the most probable cause, identifies the microorganism to species level and assesses the batches produced on the line since the last successful media fill.
- Why is a hold time study needed for Low Endotoxin Recovery (LER)? — With some formulations the endotoxin signal can drop after hours or days of storage, and a contaminated batch would give a compliant result. The study checks that endotoxin added to the undiluted product stays measurable over time.
- What grade must the room housing the sterility test isolator have? — Annex 1 sets a minimum background of Grade C for open isolators and Grade D for closed ones. The pharmacopoeias require aseptic conditions for the sterility test without naming a grade, and the choice must be justified in the CCS.
- How many colonies should a plate have to be counted? — Only plates within the countable range defined by the method are counted, often in the order of 10-300 colonies. Below that, statistical uncertainty is high; above it, colonies merge and the count underestimates.
- Who are the people listed in the Experts section? — They hold public offices in associations and societies of the field: presidents, vice-presidents, board members, secretaries. Each group cites the association’s official page from which names and roles are taken.
- Can I add the events to my calendar? — Yes. From the Events page you can download .ics files with the events that have not yet ended: all together, by month or by area (Europe, North America, Latin America, Asia, Africa, Oceania, online). The files open in Google Calendar, Outlook and Apple Calendar.
- Can past editions of an event still be consulted? — Yes. Events already held stay on the Events page, grouped by year. For the main series (PDA, ISPE, Cleanzone, CPhI, ESCMID and others) the archive starts in 2015.
- How are event dates and venues verified? — An event is listed only if the organiser’s official page gives the title, date and venue of that edition. Events without an official organiser page are not published.
- What is the ISO 17025 bodies section for? — It lists the national accreditation bodies around the world, grouped by region: Europe, North America, Latin America and the Caribbean, Middle East, Asia, Oceania, Africa. It helps check who accredits the testing and calibration laboratories of a country.
- How are the modules in the Seminars section structured? — There are six one-day modules, from M1 Laboratory microbiology to M6 Sterilisation and asepsis. The morning is theory; the afternoon has an instrument demonstration and a guided exercise.
- What are the columns? — They are twelve thematic collections that bring together the site’s content on one subject, for example bioaerosol, environmental monitoring, Annex 1, rapid microbiological methods or data integrity.
- Are there free printable sheets? — Yes, in the Resources section: the checklist of the 16 CCS elements (EU GMP Annex 1 §2.5), the quick guide to Annex 1 for Grades A and B, an environmental monitoring plan, the media fill checklist and an essential glossary.
- What is agar art? — It is drawings grown on Petri dishes with pigmented microorganisms. The page tells the story from Fleming to the ASM (American Society for Microbiology) contest, and gives the safety rules.
- How do I search for a topic across the whole site? — Use the Search page: a single search covers standards, notes, guides, glossary, directory, events and the other sections, FAQs included.
- What are the operational pillars? — They are four areas of pharmaceutical microbiology: sterility assurance, environmental monitoring, bioburden and endotoxins, antimicrobial effectiveness. Each pillar explains what is measured, the key points and the mistakes to avoid.
- How is membrane filtration performed for coliforms and E. coli? — A known volume of water, often 100 mL, is filtered through a 0.45 µm membrane. The membrane goes on a chromogenic medium (CCA) and is incubated at 36 °C for about 21 hours, following ISO 9308-1. Characteristic colonies are counted and the result is given in CFU/100 mL.
- How do you take a sample aseptically without contaminating it? — Work in Grade A with unidirectional airflow, using first air, the air that has just left the filter. Use sterile tools and disinfect the sampling point or port before opening it. The operator must not stand between the first air and the critical point.
- How do you follow plate data from sampling to trending? — At sampling, record the operator, point, date, time, volume and plate. Data move to the software without retyping, and the count after incubation goes into the same record, next to the sampling it comes from. A photo of the plate before and after counting leaves evidence that can be reviewed.
- Do EMA's Q&As on Annex 1 carry the same weight as the Annex text? — No. The text of Annex 1 is the binding one. The Q&As, published in several rounds from 2024 to 2026, clarify the practical application of points such as bioburden, rapid methods, isolators and barrier systems.